• Skip to main content
  • Skip to header right navigation
  • Skip to site footer
IMCS

IMCS

A leader in recombinant enzymes and automated micro-chromatography technologies

  • ABOUT
    • ABOUT IMCS
    • QUALITY POLICY
    • RESEARCH AT IMCS
    • CAREERS
  • PRODUCTS
    • IMCSzyme®
      • IMCSzyme E1F
      • IMCSzyme RT
      • IMCSzyme® CATALOG
    • IMCStips®
      • APPLICATIONS
        • AFFINITY
        • SIZE EXCLUSION
        • NUCLEIC ACIDS
        • ION EXCHANGE
        • REVERSE PHASE
        • PHOSPHOPEPTIDE
      • IMCStips® CATALOG
      • AUTOMATION PLATFORMS
        • DYNAMIC DEVICES
        • HAMILTON
        • INTEGRA
        • TECAN
        • OPENTRONS
        • ANALYTIK JENA
    • SULFATASES
      • Sulfazyme
      • Sulfazyme™ DS
      • Sulfazyme™ β-AS
    • GLYCO REAGENTS
      • GLYCOLIPIDS
      • ACTIVATED SUGARS
      • BIOSYNTHETIC ENZYMES
      • SMALL MOLECULES
    • SPHINGOSINES
    • OTHER PROTEINS
      • PURIFIED STREPTAVIDIN
      • B. pi. β-glucuronidase variant
  • SERVICES
    • BETA-GLUCURONIDASES & SULFATASES
      • β-GLUCURONIDASE VALIDATION SERVICES
      • HIGH-THROUGHPUT TOXICOLOGY WORKFLOWS
    • IMCStips®
      • SAMPLE PREPARATION AUTOMATION
      • HIGH-THROUGHPUT METHOD DEVELOPMENT
      • AUTOMATION PLATFORMS
        • DYNAMIC DEVICES
        • HAMILTON
        • INTEGRA
        • TECAN
        • OPENTRONS
        • ANALYTIK JENA
    • OTHER SERVICES
      • GLYCAN PRODUCTION (Coming Soon)
      • R&D COLLABORATIONS
      • EXTRACELLULAR VESICLES
  • RESOURCES
    • FAQ
    • IMCSZYME RESOURCES
    • IMCSTIPS RESOURCES
    • SAFETY DATA SHEETS
    • CERTIFICATE OF ANALYSIS
  • LATEST NEWS
    • LATEST NEWS
    • PODCAST
    • BLOG
    • EVENTS
    • WEBINARS
  • SHOP
  • CONTACT
  • en
    • en
    • es
    • fr
    • de
    • zh-CN

SizeX750 and SizeX1000 IMCStips® for desalting and buffer exchange on the Dynamic Devices platform

January 2, 2025

The expansion of IMCStips® SizeX750 and SizeX1000 on the Dynamic Devices platform offers users a simple, fast, and high-throughput solution for removing small molecules like salts, reducing agents, dyes, and buffer molecules. This enhanced product line provides improved purification capabilities, allowing users to scale up their processes beyond the limits of the SizeX100 and SizeX150 IMCStips®. With these advanced options, users can achieve more efficient...

DOWNLOAD OUR APPLICATION NOTE TO READ MORE!

DOWNLOAD OUR APPLICATION NOTE

Learn about SizeX750 and SizeX1000 IMCStips for desalting and buffer exchange on the Dynamic Devices platform!

"*" indicates required fields

Name*
Location*
Automated Liquid Handling System*
This field is hidden when viewing the form
Internal note: Please pick which application is relevant to the downloadable material. Ask Pam if you have any questions! 🙂
Contact Preferences*
Consent*

Frequently Asked Questions

Need help? Check out our FAQ section below or contact us for immediate assistance!

How are IMCStips® different from other conventional tip-based extraction products? Expand

IMCStips® contain loosely packed resin inside pipette tips retained by two porous filters. The concept is very close to batch extraction or dispersive solid phase extraction (dSPE), except the process is executed by pipetting action. Porous filters are made of standard UHDPE (ultrahigh density polyethylene), which are used in many of the aerosol filters to prevent contaminants into the pipettes. Pipettes are sourced from the original manufacturers specified for the automated liquid handlers. No chemical adhesives are used to manufacture the product, reducing concerns for leaching of chemicals.

Which automation platforms are compatible with IMCStips®? Expand

The IMCStips can be implemented across many different automation platforms, including automated liquid handlers (ALH) from Hamilton, Integra, Dynamic Devices, Tecan, Opentrons, and Analytik Jena. If you do not see your ALH platform in this list, please contact us to discuss how we can make IMCStips work for you.

Will I have to develop my own automation method to use the IMCStips®? Expand

We provide templated programs to work on specific automation platforms. Short training session, method installations and minor program adjustments will be provided by our Applications Team. Extensive modifications or customized workflows are possible at the standard rates. Examples of workflows and templated programs are provided in some of our application notes. [Related Link - IMCStips Application Notes]

What type of resin is used in IMCStips®? Expand

The types of resins used are categorized into four broad segments, affinity, ion exchange, hydrophobic interaction, and size exclusion. Many of our resins are supplied by respected and established resin manufacturers such as Cytiva, Purolite, POROS (Thermo Fisher), and Phenomenex. IMCS has other proprietary resins from other suppliers that have been customized to work for dispersive solid-phase extraction. If you have a customized resin that you would like to test using IMCStips, view our Custom Solutions page or contact us to get started.

My application is not listed in your list of applications. Are you open to working on new applications? Expand

Yes, we routinely evaluate new workflows and applications for our products. Please contact us about your particular workflow, and we will schedule a conference session with our technical team. See our Custom Solutions page for more information.

Are IMCStips endotoxin-free? Expand

We offer the option to certify that the finished products are endotoxin-free as an add-on service. Currently, only endotoxin-free plasmid purification tips are labeled as such. Please contact us if you need your IMCStips certified endotoxin-free and we will walk you through this process.

What is the binding capacity for the resins in the standard tips catalog? Expand

The binding capacity of the resin within the tips in our standard catalog would be similar to what is specified by the resin manufacturers. It can be dependent on the characteristics of your protein. Check our product sheets and posters for details of internal testing by R&D.

Can we use a manual pipette to evaluate IMCStips if we do not have an ALH? Expand

No, IMCStips are not suitable for use with manual pipettes due to several reasons. Firstly, precise control of flow rates for both aspiration and dispensing is required. Additionally, it is not ergonomic as the pipette needs to be held steadily without any movement, and the purification process can take multiple mixing cycles lasting over 30 minutes. Our technical team can help set up a proof-of-concept (PoC) demonstration by having the sample evaluated at IMCS or on a demo instrument at the customer site.

Can end-users program their own script? Expand

This is not recommended, as specific aspiration and dispense steps are required. In some cases, firmware changes may be necessary to ensure optimal recoveries from IMCStips. That's why IMCS provides a free basic script for your instrument, as well as method development, troubleshooting services, installation, and testing support. After receiving the script from IMCS application scientists, end-users are allowed to make changes to include any customizations they desire.

Can an end user make their own changes to an IMCS script? Expand

Yes. Once we provide the script, the end user can modify it as needed. However, we strongly recommend that you work with our applications team on any major changes to the method to ensure optimal performance.

How much do IMCStips cost? Expand

IMCS offers competitive pricing, with costs depending on factors such as tip type, resin type, and resin amount. For accurate pricing, please contact our technical sales team here.

Can IMCStips be reused in a CIP protocol? Expand

Yes, certain IMCStips products can be reused with an appropriate CIP protocol, as the resin will maintain its regenerative properties in IMCStips. However, the end-user must develop appropriate SOPs to determine their effectiveness, as results may vary.

Can IMCStips be filled with a custom resin of an end user’s choice? Expand

Yes, our technical team can review the resin specifications to determine if it is compatible with IMCStips. One important requirement is that the bead size must be over 50 μm. Contact our team here to learn more and get started.

What is the maximum amount of resin that can be filled in different sizes of IMCStips, manufactured in a 300 µL IMCStip? A 1 mL IMCStip? A 5 mL IMCStip? Expand

Different ALH (Automated Liquid Handling) systems offer various tip sizes, and the maximum fill depends on the resin used. Here are some examples of the most commonly used tip sizes and their maximum resin fills:

1 mL - 100 µL
300 µL - 10 µL
5 mL - 250 µL

Does IMCStips require any specialized labware on the ALHs to support its purification workflows? Expand

No, IMCStips only require the standard labware available on most ALHs.

Do IMCStips require specific buffers for optimal function? Expand

IMCS will recommend buffers depending on the application but can work with you to optimize the method for your specific needs.

Does the IMCStips script come with instructions? How hard is it to use the script and method? Expand

Yes, IMCS provides comprehensive user guidelines to help you navigate the method. Additionally, the script features an intuitive graphical user interface (GUI) designed for easy navigation, requiring minimal training.

Ready to get started? Contact us today for a free sample!

Get Started
Category: BLOG, LATEST NEWSTag: imcstips
Previous Post:Using IMCStips with INTEGRA ASSIST+ and VIAFLO 96 for Affinity Purification
Next Post:Comparison of different anion exchange resins in IMCStips to assess binding capacities

Sidebar

"*" indicates required fields

Name*
Email me a copy
Consent

Customize Your Workflow

IMCS recognizes our customers’ needs vary, which is why we provide tailored tools and services to help you reach your laboratory’s goals.

VIEW OUR CUSTOM SOLUTIONS

ABOUT IMCS

INTEGRATED MICRO-CHROMATOGRAPHY SYSTEMS, INC. (IMCS) IS A BIOTECHNOLOGY COMPANY FOCUSED ON DELIVERING TOOLS AND SERVICES THAT HELP PAVE THE WAY FOR THE FUTURE OF PRECISION MEDICINE. WE STRIVE TO ADDRESS THE GROWING NEEDS OF CLINICAL AND RESEARCH LABORATORIES THROUGH ADVANCED TECHNOLOGIES THAT INCREASE TESTING EFFICIENCY AND ACCURACY.

STAY UP TO DATE

WANT REGULAR UPDATES ON OUR INNOVATIVE PRODUCTS?
Sign up to receive exclusive emails and offers from IMCS.
!
!
!
Subscribe
Something went wrong. Please check your entries and try again.

ABOUT

ABOUT IMCS

CAREERS

QUALITY POLICY

RESEARCH AT IMCS

PRODUCTS

IMCSZYME

IMCSZYME RT

IMCSTIPS

PROTEINS, ENZYMES, RESINS

GLYCO REAGENTS

TERMS

TERMS OF USE

PRIVACY POLICY

STANDARD TERMS AND CONDITIONS

FCOI POLICY

CONNECT WITH US

IMCS, Inc. Headquarters
110 Centrum Drive
Irmo, SC 29063

  • IMCS LinkedIn Page
  • IMCS Facebook Page
  • IMCS Twitter Page

COPYRIGHT © 2026 · IMCS · ALL RIGHTS RESERVED ·

Return to top

Get Started Today!

Please fill out the form below to get started.

"*" indicates required fields

Step 1 of 3

33%
Which IMCStips applications you are interested in? Please select all that apply.*
Name*
Automated Liquid Handling System*
Consent*

Caleb-Schlachter-for-web

Caleb R. Schlachter, Ph.D.

Principal Scientist
Caleb R. Schlachter, Ph.D., as the Principal Scientist at IMCS, leads and provides guidance for several research and development projects that involve proteins, including enzymes for glycan hydrolysis and glycan synthesis. He has co-authored multiple patents, posters, and peer-reviewed articles on β-glucuronidases and sulfatases.
Gray Amick for web

Gray D. Amick, Ph.D.

Director of Operations
Gray D. Amick, Ph.D., is the Director of Operations at IMCS with over 26 years of experience in forensic DNA analysis and toxicology. Prior to joining IMCS, he led forensic DNA testing for the Richland County Sheriff’s Department as technical leader and lab director. He has been court-qualified as an expert over 100 times and has authored and co-authored multiple posters and peer-reviewed articles.
Amanda M Headshot

Amanda C. McGee

Research Scientist
Amanda C. McGee is a Research Scientist at IMCS involved with enzyme characterizations, new analytical method developments, and advanced technical support. She joined IMCS with several years of experience in analytical testing for active pharmaceutical ingredients as per cGMP, USP and ICH guidelines. She has co-authored peer reviewed articles in the Journal of Analytical Toxicology and presented research at national and international conferences.
Andrew_Headshot

L. Andrew Lee, Ph.D.

Co-Founder and Chief Scientific Officer
L. Andrew Lee, Ph.D. co-founded IMCS and leads research and development efforts in enzyme engineering and automated micro-chromatography workflows. He directs new market efforts in glycan synthesis, supported by three NIH Fast-Track awards.

Get started with 2N1 below

"*" indicates required fields

Name*
Would you be interested in joining the 2N1 beta program?*
Which product are you interested in? (select all that apply)*
What are your current purification workflows? (select all that apply)*
Please select your automation platform(s) (select all that apply)*
How soon are you planning on evaluating 2N1?*
Consent*

DOWNLOAD OUR POSTERS

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Please select the posters you would like to download*
Name*
Please provide a valid email so we can send you the download link.
Location*
Automated Liquid Handling System
Contact preferences*
Consent*

Podcast Form

"*" indicates required fields

Name*
How would you like to connect?*
Please let us know what's on your mind. Have a question for us? Ask away.

Ready for a change? Get your FREE sample of IMCSzyme® RT today.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*
Consent*