• Skip to main content
  • Skip to header right navigation
  • Skip to site footer
IMCS

IMCS

Integrated Micro-Chromatography Systems, Inc (IMCS) is a biotechnology company focused on delivering tools and services to...

  • ABOUT
    • ABOUT IMCS
    • QUALITY POLICY
    • RESEARCH AT IMCS
    • CAREERS
  • PRODUCTS
    • IMCSzyme®
      • IMCSzyme E1F
      • IMCSzyme RT
      • IMCSzyme® CATALOG
    • IMCStips®
      • APPLICATIONS
        • AFFINITY
        • SIZE EXCLUSION
        • NUCLEIC ACIDS
        • ION EXCHANGE
        • REVERSE PHASE
        • PHOSPHOPEPTIDE
      • IMCStips® CATALOG
      • AUTOMATION PLATFORMS
        • DYNAMIC DEVICES
        • HAMILTON
        • INTEGRA
        • TECAN
        • OPENTRONS
        • ANALYTIK JENA
    • SULFATASES
      • Sulfazyme™ PaS
      • Sulfazyme™ DS
      • Sulfazyme™ β-AS
    • GLYCO REAGENTS
      • GLYCOLIPIDS
      • ACTIVATED SUGARS
      • BIOSYNTHETIC ENZYMES
      • SMALL MOLECULES
    • SPHINGOSINES
    • OTHER PROTEINS
      • PURIFIED STREPTAVIDIN
      • B. pi. β-glucuronidase variant
  • SERVICES
    • BETA-GLUCURONIDASES & SULFATASES
      • β-GLUCURONIDASE VALIDATION SERVICES
      • HIGH-THROUGHPUT TOXICOLOGY WORKFLOWS
    • IMCStips®
      • SAMPLE PREPARATION AUTOMATION
      • HIGH-THROUGHPUT METHOD DEVELOPMENT
      • AUTOMATION PLATFORMS
        • DYNAMIC DEVICES
        • HAMILTON
        • INTEGRA
        • TECAN
        • OPENTRONS
        • ANALYTIK JENA
    • OTHER SERVICES
      • GLYCAN PRODUCTION (Coming Soon)
      • R&D COLLABORATIONS
      • EXTRACELLULAR VESICLES
  • RESOURCES
    • FAQ
    • IMCSZYME RESOURCES
    • IMCSTIPS RESOURCES
    • SAFETY DATA SHEETS
    • CERTIFICATE OF ANALYSIS
  • LATEST NEWS
    • LATEST NEWS
    • PODCAST
    • BLOG
    • EVENTS
    • WEBINARS
  • CONTACT
  • en
    • en
    • es
    • fr
    • de
    • zh-CN

Maximizing Yield from Nucleic Acid Extraction/Purification: A Troubleshooting Guide

December 18, 2023

Nucleic acid extraction or purification is crucial in various molecular biology experiments. Several methods are available for nucleic acid extraction or purification, including phenol-chloroform extraction, spin column extraction, and magnetic bead purification. Here are some problems and solutions to maximize yield from these methods:

Table of Contents
    Add a header to begin generating the table of contents

    PHENOL-CHLOROFORM EXTRACTION

    Problem 1: Incomplete homogenization

    Incomplete homogenization can occur when the sample is not ground to a fine powder or when a tissue homogenizer is not used to disrupt the cells properly. As a result, the nucleic acids may not be released from the cells effectively, leading to low yield.

    If grinding the tissue to a fine powder, it's essential to avoid over-drying the tissue, as this can result in DNA degradation. Similarly, when using a tissue homogenizer, selecting the appropriate speed and duration is important to ensure efficient cell disruption. Proper homogenization guarantees the effective release of nucleic acids from the cells. Lysis buffers and sonication can also aid in further breaking down the cells and releasing nucleic acids from the sample.

    Problem 2: Poor phase separation

    Poor phase separation during phenol-chloroform extraction can lead to the loss of nucleic acids. This can occur when the sample is not mixed properly with phenol and chloroform or when the centrifugation speed or duration is not appropriate. As a result, the nucleic acids may remain in the wrong phase or may not be extracted efficiently, leading to low yield.

    It is important to ensure that the sample is mixed properly with phenol and chloroform and that the centrifugation speed and duration are appropriate. The sample should be mixed gently but thoroughly with phenol and chloroform to ensure that the nucleic acids are extracted efficiently. Additionally, the centrifugation speed and duration should be optimized to ensure proper phase separation. If the sample is not centrifuged for a sufficient duration, the phases may not separate effectively, leading to low yield. On the other hand, if the centrifugation speed is too high, the nucleic acids may be lost to the organic phase, leading to low yield as well.

    Problem 3: DNA or RNA degradation

    DNA or RNA degradation can occur due to the presence of nucleases, which are enzymes that degrade nucleic acids. This can occur during the extraction process or during storage of the samples. As a result, the yield of nucleic acids may be low or the quality may be poor.

    It is crucial to use nuclease-free solutions and equipment and to handle the samples with care to avoid the introduction of nucleases into the sample. Excessive shaking or vortexing should be avoided as it can cause mechanical shearing of DNA or RNA. And to prevent RNA degradation during the extraction process, RNase inhibitors can be added.

    Problem 4: Protein contamination

    Protein contamination can occur when the proteins are not removed from the sample effectively during the extraction process.

    To address this problem, it is important to use proteinase K treatment or perform an additional chloroform extraction step to remove proteins. Proteinase K treatment can digest the proteins and remove them from the sample. Additionally, the use of phase-lock gel tubes or phase-prep tubes can help to remove proteins. These tubes contain a gel that can selectively bind proteins, allowing the nucleic acids to be recovered in the aqueous phase. Finally, an additional chloroform extraction can be performed to remove any remaining proteins. The aqueous phase can then be collected for further nucleic acid purification. It is important to note that excessive protein removal can lead to lower yield, so it is important to optimize the protein removal step for each sample.

    Problem 5: pH instability

    pH instability can result in the loss of nucleic acids or the formation of precipitates during nucleic acid extraction using phenol-chloroform. This can occur when the pH of the sample is not maintained during the extraction process.

    It is important to select the appropriate buffer for the extraction and to monitor the pH of the sample during the extraction process. Tris-HCl or TE buffer is commonly used for nucleic acid extraction, as they have a buffering capacity that can maintain the pH of the sample. Additionally, it is important to use fresh buffers and to ensure that the pH of the buffer is checked and adjusted if necessary. pH paper or a pH meter can be used to monitor the pH of the sample during the extraction process. By maintaining the appropriate pH, the loss of nucleic acids or the formation of precipitates can be minimized.

    Problem 6: Low elution volume

    Low elution volume can result in a low yield of nucleic acids during phenol-chloroform extraction. This can occur when the elution buffer volume is not optimized for the amount of starting material or when the sample is not properly centrifuged to elute the nucleic acids.

    The elution buffer volume should be optimized based on the amount of starting material to ensure that the nucleic acids are properly eluted. Additionally, the sample should be centrifuged for a sufficient duration and at an appropriate speed to ensure that the nucleic acids are fully eluted from the column or tube. If necessary, the elution buffer can be preheated to increase the yield of nucleic acids.

    RELATED SOLUTIONS: NUCLEIC ACID PURIFICATION WITH IMCStips®
    IMCStips are pipette tip-based micro-chromatography columns that utilize patented dispersive solid-phase extraction (dSPE) technology to provide high-quality, high-throughput automated nucleic acid purification: from transfection-grade plasmid DNA for your minipreps to PCR cleanup and NGS library preparation. LEARN MORE

    SPIN COLUMN EXTRACTION

    Problem 1: Insufficient sample lysis

    One of the common problems in spin column-based nucleic acid extraction is insufficient sample lysis. Incomplete cell lysis can lead to lower yield due to the incomplete release of nucleic acids from cells or tissues. This can happen due to inadequate lysis buffer, suboptimal lysis conditions, or short incubation times. Insufficient lysis can also cause the release of nuclease enzymes from the cells, which can degrade the nucleic acids, leading to lower yield and poor quality of the extracted nucleic acids.

    It is important to ensure complete cell lysis. This can be achieved by using an appropriate lysis buffer, optimizing lysis conditions such as pH, temperature, and duration of incubation, and using longer incubation times. The use of detergents such as Triton X-100 or SDS in the lysis buffer can enhance cell lysis by disrupting the cell membrane. Additionally, the use of mechanical methods such as bead beating or sonication can help to break down the cells and enhance nucleic acid release. It is also essential to avoid overloading the spin column with too much sample, as this can lead to incomplete lysis.

    Problem 2: Inefficient binding

    Another problem that can affect the yield of nucleic acids obtained from spin column-based extraction is inefficient binding of nucleic acids to the spin column. This can happen due to inadequate mixing of the binding buffer and the sample, or due to the presence of contaminants that interfere with nucleic acid binding.

    To improve binding efficiency, it is important to ensure proper mixing of the sample and the binding buffer. The binding buffer should also have the appropriate pH and salt concentration for optimal nucleic acid binding. Pre-washing the column with the wash buffer can help to remove any contaminants that may interfere with binding. Additionally, the use of chaotropic salts such as guanidine or ammonium sulfate in the binding buffer can enhance nucleic acid binding. It is also essential to avoid overloading the spin column with too much sample, as this can lead to inefficient binding.

    Problem 3: Incomplete washing

    Incomplete washing is another problem that can result in low yield and poor quality of the extracted nucleic acids. Incomplete washing can result in residual impurities in the final eluate, leading to poor quality and lower yield of nucleic acids.

    To avoid incomplete washing, it is essential to perform the recommended number of washes with the appropriate wash buffer. The wash buffer should be added to the spin column in small volumes and allowed to flow through completely before adding the next wash buffer. It is also important to centrifuge the spin column for the recommended duration to ensure efficient washing. If residual impurities are still present in the eluate, additional washes may be necessary.

    Problem 4: Low elution volume

    Low elution volume can result in lower yield of nucleic acids. This can happen when the recommended elution buffer volume is not used, or elution is performed at suboptimal temperature or duration.

    To increase the elution volume, it is recommended to use a higher volume of elution buffer and to let the column incubate with the buffer for a few minutes before centrifugation. Additionally, warming the elution buffer to 60-70°C can help to improve the yield by reducing the viscosity of the buffer and promoting better flow through the column. It is important to note that using too much elution buffer can dilute the nucleic acid, so the recommended volume should be followed.

    MAGNETIC BEAD PURIFICATION

    Problem 1: Incomplete bead resuspension

    Incomplete resuspension of the magnetic beads can lead to uneven binding of nucleic acids and reduced yield. This can happen when the magnetic beads are not fully dispersed, resulting in clumps of beads that do not come into contact with the sample. This can result in lower yields of nucleic acids because there are fewer beads to bind to the nucleic acids.

    To ensure complete bead resuspension, it is recommended to gently vortex the beads until they are completely dispersed and homogenous. Incomplete bead resuspension can also be avoided by using pre-made bead solutions that do not require any further preparation. By properly resuspending the beads, the binding capacity of the beads is optimized, leading to higher yields of nucleic acids.

    Problem 2: Inadequate washing

    Inadequate washing of the magnetic beads can lead to the presence of contaminants, such as residual salts or detergents, which can inhibit downstream applications or interfere with yield. This can happen when the beads are not washed properly, leading to residual contaminants that interfere with the nucleic acid extraction or subsequent applications.

    Adequate washing of magnetic beads is necessary to remove residual contaminants that can interfere with downstream applications. Washing the beads thoroughly with buffer solutions and centrifugation can help to ensure complete removal of contaminants. By washing the beads properly, the purity of the nucleic acid sample is improved, leading to better yields and downstream applications.

    Problem 3: Over-drying of the beads

    Over-drying of the magnetic beads can cause the beads to clump together, reducing their surface area and hence, reducing their binding capacity. This can happen when the beads are allowed to dry too much, leading to clumping that reduces their surface area and hence their binding capacity.

    Over-drying can be avoided by drying the beads with a brief centrifugation and removing any excess liquid by pipetting, leaving the beads slightly damp. By avoiding over-drying, the binding capacity of the beads is optimized, leading to higher yields of nucleic acids.

    Problem 4: Incomplete elution

    Incomplete elution can result in a loss of nucleic acid yield and purity. This can happen when the elution buffer is not effective at releasing the nucleic acids from the beads or when the elution step is not carried out properly.

    Proper elution can be achieved by adding the appropriate elution buffer and incubating at the recommended temperature and time, followed by centrifugation. Repeating the elution step or increasing the elution volume can help to ensure complete elution. By optimizing the elution step, the yield and purity of the nucleic acid sample can be improved, leading to better downstream applications.

    Conclusion

    Obtaining optimal yields from nucleic acid extraction and purification requires careful consideration of several factors, including sample preparation, phase separation, and enzyme activity. This guide provides solutions to common challenges in phenol-chloroform extraction, spin column extraction, and magnetic bead purification. These solutions include homogenization, phase separation, DNA/RNA degradation, and protein contamination.

    Understanding the principles of each step and troubleshooting issues can improve the yields from nucleic acid extraction, leading to greater productivity in the lab. For labs with automation capabilities and high-throughput needs, however,  automated tip-based nucleic acid purification with IMCStips® is worth exploring. This high-throughput, automated technology uses dispersive solid-phase extraction and strong cation resins to deliver transfection-grade plasmid DNA, up to 96 samples in less than one hour. Fill out the form below to request a free sample, or visit our IMCStips Nucleic Acids page to learn more.

    Ready to get started? Contact us today for a free sample!

    Get Started
    Category: BLOG
    Previous Post:In-well hydrolysis at room temperature with IMCSzyme® RT and β-Gone™ Plus
    Next Post:Episode 0: IMCS Podcast Trailer

    Customize Your Workflow

    IMCS recognizes our customers’ needs vary, which is why we provide tailored tools and services to help you reach your laboratory’s goals.

    VIEW OUR CUSTOM SOLUTIONS

    ABOUT IMCS

    INTEGRATED MICRO-CHROMATOGRAPHY SYSTEMS, INC. (IMCS) IS A BIOTECHNOLOGY COMPANY FOCUSED ON DELIVERING TOOLS AND SERVICES THAT HELP PAVE THE WAY FOR THE FUTURE OF PRECISION MEDICINE. WE STRIVE TO ADDRESS THE GROWING NEEDS OF CLINICAL AND RESEARCH LABORATORIES THROUGH ADVANCED TECHNOLOGIES THAT INCREASE TESTING EFFICIENCY AND ACCURACY.

    STAY UP TO DATE

    WANT REGULAR UPDATES ON OUR INNOVATIVE PRODUCTS?
    Sign up to receive exclusive emails and offers from IMCS.
    !
    !
    !
    Subscribe
    Something went wrong. Please check your entries and try again.

    ABOUT

    ABOUT IMCS

    CAREERS

    QUALITY POLICY

    RESEARCH AT IMCS

    PRODUCTS

    IMCSZYME

    IMCSZYME RT

    IMCSTIPS

    PROTEINS, ENZYMES, RESINS

    GLYCO REAGENTS

    TERMS

    TERMS OF USE

    PRIVACY POLICY

    STANDARD TERMS AND CONDITIONS

    FCOI POLICY

    CONNECT WITH US

    IMCS, Inc. Headquarters
    110 Centrum Drive
    Irmo, SC 29063

    • IMCS LinkedIn Page
    • IMCS Facebook Page
    • IMCS Twitter Page

    COPYRIGHT © 2025 · IMCS · ALL RIGHTS RESERVED ·

    Return to top

    We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept”, you consent to the use of ALL the cookies.
    Do not sell my personal information.
    Cookie InfoACCEPT

    Privacy Overview

    This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are as essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
    Necessary
    Always Enabled
    Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
    Non-necessary
    Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
    Functional
    Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
    CookieDurationDescription
    __cf_bm30 minutesCloudflare set the cookie to support Cloudflare Bot Management.
    li_gc5 months 27 daysLinkedin set this cookie for storing visitor's consent regarding using cookies for non-essential purposes.
    lidc1 dayLinkedIn sets the lidc cookie to facilitate data center selection.
    UserMatchHistory1 monthLinkedIn sets this cookie for LinkedIn Ads ID syncing.
    Performance
    Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
    CookieDurationDescription
    SRM_B1 year 24 daysUsed by Microsoft Advertising as a unique ID for visitors.
    Analytics
    Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
    CookieDurationDescription
    _clck1 yearMicrosoft Clarity sets this cookie to retain the browser's Clarity User ID and settings exclusive to that website. This guarantees that actions taken during subsequent visits to the same website will be linked to the same user ID.
    _clsk1 dayMicrosoft Clarity sets this cookie to store and consolidate a user's pageviews into a single session recording.
    _fbp3 monthsFacebook sets this cookie to display advertisements when either on Facebook or on a digital platform powered by Facebook advertising after visiting the website.
    _ga1 year 1 month 4 daysGoogle Analytics sets this cookie to calculate visitor, session and campaign data and track site usage for the site's analytics report. The cookie stores information anonymously and assigns a randomly generated number to recognise unique visitors.
    _ga_*1 year 1 month 4 daysGoogle Analytics sets this cookie to store and count page views.
    _gat_gtag_UA_*1 minuteGoogle Analytics sets this cookie to store a unique user ID.
    _gcl_au3 monthsGoogle Tag Manager sets the cookie to experiment advertisement efficiency of websites using their services.
    _gid1 dayGoogle Analytics sets this cookie to store information on how visitors use a website while also creating an analytics report of the website's performance. Some of the collected data includes the number of visitors, their source, and the pages they visit anonymously.
    _s30 minutesThis cookie is associated with Shopify's analytics suite.
    _shopify_s30 minutesThis cookie is associated with Shopify's analytics suite.
    _shopify_y1 year 1 month 4 daysThis cookie is associated with Shopify's analytics suite.
    _y1 year 1 month 4 daysThis cookie is associated with Shopify's analytics suite.
    AnalyticsSyncHistory1 monthLinkedin set this cookie to store information about the time a sync took place with the lms_analytics cookie.
    CLID1 yearMicrosoft Clarity set this cookie to store information about how visitors interact with the website. The cookie helps to provide an analysis report. The data collection includes the number of visitors, where they visit the website, and the pages visited.
    CONSENT2 yearsYouTube sets this cookie via embedded YouTube videos and registers anonymous statistical data.
    ln_or1 dayLinkedin sets this cookie to registers statistical data on users' behaviour on the website for internal analytics.
    MR7 daysThis cookie, set by Bing, is used to collect user information for analytics purposes.
    SMsessionMicrosoft Clarity cookie set this cookie for synchronizing the MUID across Microsoft domains.
    vuid1 year 1 month 4 daysVimeo installs this cookie to collect tracking information by setting a unique ID to embed videos on the website.
    Advertisement
    Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.
    CookieDurationDescription
    ANONCHK10 minutesThe ANONCHK cookie, set by Bing, is used to store a user's session ID and verify ads' clicks on the Bing search engine. The cookie helps in reporting and personalization as well.
    bcookie1 yearLinkedIn sets this cookie from LinkedIn share buttons and ad tags to recognize browser IDs.
    bscookie1 yearLinkedIn sets this cookie to store performed actions on the website.
    IDE1 year 24 daysGoogle DoubleClick IDE cookies store information about how the user uses the website to present them with relevant ads according to the user profile.
    li_sugr3 monthsLinkedIn sets this cookie to collect user behaviour data to optimise the website and make advertisements on the website more relevant.
    MUID1 year 24 daysBing sets this cookie to recognise unique web browsers visiting Microsoft sites. This cookie is used for advertising, site analytics, and other operations.
    test_cookie15 minutesdoubleclick.net sets this cookie to determine if the user's browser supports cookies.
    VISITOR_INFO1_LIVE5 months 27 daysYouTube sets this cookie to measure bandwidth, determining whether the user gets the new or old player interface.
    VISITOR_PRIVACY_METADATA5 months 27 daysYouTube is a Google-owned platform for hosting and sharing videos. YouTube collects user data through videos embedded in websites, which is aggregated with profile data from other Google services in order to display targeted advertising to web visitors across a broad range of their own and other websites.
    YSCsessionYoutube sets this cookie to track the views of embedded videos on Youtube pages.
    yt-remote-connected-devicesneverYouTube sets this cookie to store the user's video preferences using embedded YouTube videos.
    yt-remote-device-idneverYouTube sets this cookie to store the user's video preferences using embedded YouTube videos.
    yt.innertube::nextIdneverYouTube sets this cookie to register a unique ID to store data on what videos from YouTube the user has seen.
    yt.innertube::requestsneverYouTube sets this cookie to register a unique ID to store data on what videos from YouTube the user has seen.
    Others
    Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet.
    SAVE & ACCEPT
    Powered by CookieYes Logo

    Get Started Today!

    Please fill out the form below to get started.

    "*" indicates required fields

    Step 1 of 3

    33%
    Which IMCStips applications you are interested in? Please select all that apply.*
    Name*
    Automated Liquid Handling System*
    Consent*

    DOWNLOAD OUR POSTERS

    "*" indicates required fields

    Please select the posters you would like to download*
    Name*
    Please provide a valid email so we can send you the download link.
    Location*
    Automated Liquid Handling System
    Contact preferences*
    Consent*
    This field is for validation purposes and should be left unchanged.

    Podcast Form

    "*" indicates required fields

    Name*
    How would you like to connect?*
    Please let us know what's on your mind. Have a question for us? Ask away.

    Ready for a change? Get your FREE sample of IMCSzyme® RT today.

    "*" indicates required fields

    Name*
    Location*
    Consent*
    This field is for validation purposes and should be left unchanged.