MORE FREEDOM FOR YOUR LAB AUTOMATION
IMCStips is a pipette tip-based technology using patented dispersive solid-phase extraction (dSPE) for efficient analyte purification. Its loosely packed resin maximizes contact time through turbulent mixing, while compatibility with automated liquid handlers enables high-throughput workflows. This results in reliable purifications in a shorter amount of time.
IMCStips are designed to be fully compatible with the Opentrons Flex® robot. Coupled with optimized and validated protocols, using IMCStips on the Opentrons platform enables rapid and dependable automated workflows.

Tip Size | Resin Amount | Tip Quantity | Catalog Number | Category | Platform | Resin | Resin Type | Sample Volume |
---|---|---|---|---|---|---|---|---|
1 mL | 5 µL | 8 | 04T-P1R72-1-5-8 | Affinity | Opentrons | Ni Sepharose 6 Fast Flow | Ni-IMAC | |
1 mL | 5 µL | 96 | 04T-P1R72-1-5-96 | Affinity | Opentrons | Ni Sepharose 6 Fast Flow | Ni-IMAC | |
1 mL | 10 µL | 8 | 04T-P1R72-1-10-8 | Affinity | Opentrons | Ni Sepharose 6 Fast Flow | Ni-IMAC | |
1 mL | 10 µL | 96 | 04T-P1R72-1-10-96 | Affinity | Opentrons | Ni Sepharose 6 Fast Flow | Ni-IMAC | |
1 mL | 25 µL | 8 | 04T-P1R72-1-25-8 | Affinity | Opentrons | Ni Sepharose 6 Fast Flow | Ni-IMAC | |
1 mL | 25 µL | 96 | 04T-P1R72-1-25-96 | Affinity | Opentrons | Ni Sepharose 6 Fast Flow | Ni-IMAC | |
1 mL | 10 µL | 8 | 04T-P1R72XL-1-10-8 | Affinity | Opentrons | Ni Sepharose Excel | Ni-IMAC | |
1 mL | 10 µL | 96 | 04T-P1R72XL-1-10-96 | Affinity | Opentrons | Ni Sepharose Excel | Ni-IMAC | |
1 mL | 25 µL | 8 | 04T-P1R72XL-1-25-8 | Affinity | Opentrons | Ni Sepharose Excel | Ni-IMAC | |
1 mL | 25 µL | 96 | 04T-P1R72XL-1-25-96 | Affinity | Opentrons | Ni Sepharose Excel | Ni-IMAC | |
1 mL | 8 | 04T-P1R76-0-220-8 | Size Exclusion | Opentrons | SizeX100 | Size Exclusion | 100 µL | |
1 mL | 96 | 04T-P1R76-0-220-96 | Size Exclusion | Opentrons | SizeX100 | Size Exclusion | 100 µL | |
1 mL | 8 | 04T-P1R76-0-350-8 | Size Exclusion | Opentrons | SizeX150 | Size Exclusion | 150 µL | |
1 mL | 96 | 04T-P1R76-0-350-96 | Size Exclusion | Opentrons | SizeX150 | Size Exclusion | 150 µL | |
1 mL | 10 µL | 8 | 04T-P1R80-1-10-8 | Affinity | Opentrons | MabSelect SuRe LX | Protein A | |
1 mL | 10 µL | 96 | 04T-P1R80-1-10-96 | Affinity | Opentrons | MabSelect SuRe LX | Protein A | |
1 mL | 25 µL | 8 | 04T-P1R80-1-25-8 | Affinity | Opentrons | MabSelect SuRe LX | Protein A | |
1 mL | 25 µL | 96 | 04T-P1R80-1-25-96 | Affinity | Opentrons | MabSelect SuRe LX | Protein A | |
1 mL | 50 µL | 8 | 04T-P1R80-1-50-8 | Affinity | Opentrons | MabSelect SuRe LX | Protein A | |
1 mL | 50 µL | 96 | 04T-P1R80-1-50-96 | Affinity | Opentrons | MabSelect SuRe LX | Protein A | |
1 mL | 10 µL | 8 | 04T-P1R80A-1-10-8 | Affinity | Opentrons | MabSelect PrismA | Protein A | |
1 mL | 10 µL | 96 | 04T-P1R80A-1-10-96 | Affinity | Opentrons | MabSelect PrismA | Protein A | |
1 mL | 25 µL | 8 | 04T-P1R80A-1-25-8 | Affinity | Opentrons | MabSelect PrismA | Protein A | |
1 mL | 25 µL | 96 | 04T-P1R80A-1-25-96 | Affinity | Opentrons | MabSelect PrismA | Protein A | |
1 mL | 50 µL | 8 | 04T-P1R80A-1-50-8 | Affinity | Opentrons | MabSelect PrismA | Protein A |
Binding Kinetics of His-tagged GFP with IMCStips

This figure shows the binding kinetics of His-tagged GFP using IMCStips with Nickel 6 Fast Flow resin at 25 μL (left) and 50 μL (right) resin volumes. The amount of GFP bound (mg) is plotted against binding cycles for different initial concentrations. Higher resin volumes (50 μL) result in greater binding capacity.